TA652FH-W Demo Dashboards Usage¶
Overview¶
There are some dashboards related to TA652FH-W, namely TA652FH-W Thermostat List
, TA652FH-W Thermostat (For Mobile App)
and Office center - TA652FH-W Thermostats
. We open the former to start operating TA652FH-W.
Dashboard | Description | For Web UI | For Mobile App | Entry* |
---|---|---|---|---|
TA652FH-W Thermostat List* | list | Yes | No | Yes |
TA652FH-W Thermostat (For Mobile App) | details | Yes | Yes | No |
Office center - TA652FH-W Thermostats** | list & details | Yes | Yes | Yes |
Hint
- If Entry is Yes, then directly enter the Dashboard and there will be data displayed.
- If Entry is No, there will be no data display when entering this Dashboard directly, and you need to jump to this Dashboard from other Dashboards.
TA652FH-W Thermostat List
depends onTA652FH-W Thermostat (For Mobile App)
.Office center - TA652FH-W Thermostats
can be used independently.
TA652FH-W Thermostat List¶
Dashboard states¶
Default state¶
Default state
is root state.
- Dashboard bar:
- : Click here to skip to root state. Since default state is root state, click here and there is no response.
- : Click the two ICONS in the upper left corner to display the page in full screen.
- : Edit time window.
- Thermostats widgets:
- Fields:
- Device name, Label, Type, active.
- Room temperature, Floor Temperature, Setpoint, Unit: Refer to Monitor state.
- Actions:
- : skip to TA652FH-W Thermostat (For Mobile App).
- : Popup dialog to editing a device’s label.
Import List Dashboard¶
Tip
A Dashboard file can only be imported once. If you have already imported it, you do not need and cannot repeat the import.
If you have already imported it, you can skip this step.
In order to use this dashboard, you must to create TA652FH-W Thermostat Device Profile
and TA652FH-W Thermostat (For Mobile App)
. If they don’t exist, you can import them. See Import Device Profile of TA652FH-W Thermostat or Import TA652FH-W Detail Dashboard.
First, you can import this dashboard.
- Download
ta652fh_w_thermostat_list.json
. - Dashboards –> + –> Popup dialog: Import dashboard –> Drag and drop list dashboard File –> Import.
Next, modify a action’s target dashboard and target dashboard state.
- Dashboards –> Click my list dashboard
- Edit (red icon on the bottom and right)
- Enter Edit Dashboard Mode –> Edit Widget (icon)
- Action –> Edit Action (icon)
- Modify Target dashboard –> modify Target dashboard state –> Save
These values are shown in the following table:
Field | Value |
---|---|
Target dashboard | TA652FH-W Thermostat (For Mobile App) |
Target dashboard state | monitor |
- Apply changes (red icon)
- Apply changes (red icon on the bottom and right)
Update List Dashboard¶
TA652FH-W Thermostat (For Mobile App)¶
Dashboard states¶
Monitor state¶
Monitor state
is root state.
- Dashboard bar:
Hidden. Refer Default state.
- Widgets:
Widget Description MONITOR skip to Monitor state CONTROL skip to Control state PROGRAM skip to Program state SETTINGS skip to Settings state ADMIN skip to Admin state Room Temperature room temperature Floor Temperature floor temperature Setpoint current setpoint value Temperature history Room temperature & Change Over Sensor temperaturehistory. Clickto edit this timewindow. Refer to Default state
Control state¶
- Dashboard bar:
Hidden. Refer to Default state.
- Widgets:
Widget Description Setpoint If you adjust setpoint, override program status is YES (true) Program program on or off PRG next setpoint next program time & setpoint Override program status “YES”(true) or “NO”(false) Control Mode “Off” or “On”
Program state¶
- Dashboard bar:
Hidden. Refer to Default state.
- Widgets:
Program Mode Description NO PROGRAM Program disabled 1 DAY (MON) Using 4 set points of Monday every day 1+5+1 (SUN+MON+SAT) Using 4 set points of Monday from Monday to Friday 7 DAYS (SUN~SAT) Using 4 set points every day Sunday, … Skip to Program_setpoints state
Program_setpoints state¶
- Dashboard bar:
Hidden. Refer to Default state.
- Widgets:
Widget Description Program 1 ~ Program 4 time, hour:minute Setpoint 1 ~ Setpoint 4 setpoint value, temperature
Settings state¶
- Dashboard bar:
Hidden. Refer to Default state.
- Widgets:
Widget Description Temp Unit “°C” or “°F”. Reboot the device to take effect Adaptive control Enabled or disabled System Mode “Heat” or “Cool” Sensor Mode “Internal” / “External” / “Combined” senosr can be selectedwhen it is in “Heat” mode.Only “Internal” Sensor will be used when it is in “Cool” mode.Floor temperature limited external sensor temperature offset Temp Offset(Internal Sensor) Internal sensor temperature offset Switching Diff Heating Switching differential heating Switching Diff Cooling Switching differential cooling
Admin state¶
- Dashboard bar:
Hidden. Refer to Default state.
- Widgets:
Widget Description Time Format “12 Hours” or “24 Hours” Timezone See Step 4.2 Add shared attributes of new device NTP Server SNTP protocol server URL, e.g. pool.ntp.org,0.pool.ntp.org, 1.pool.ntp.org,time.nist.gov, …Sync Time Sync time per syncTimeFreq seconds.If you change Timezone or NTP Server, you have to do it.Device attributes Device name, device profile (type), device label,model, MAC, device Wi-Fi Module F/W version,device Main MCU F/W versionReboot Reboot device Clear Wi-Fi Config Clear device’s Wi-Fi configuration
Import Detail Dashboard¶
Tip
A Dashboard file can only be imported once. If you have already imported it, you do not need and cannot repeat the import.
If you have already imported it, you can skip this step.
In order to use this dashboard, you must to create TA652FH-W Thermostat Device Profile
. If it doesn’t exist, you can import it. See Import Device Profile of TA652FH-W Thermostat.
- Download
ta652fh_w_thermostat__for_mobile_app_.json
. - Dashboards –> + –> Popup dialog: Import dashboard –> Drag and drop detail dashboard File –> Import.
- Optional, This dashboard can be set as
TA652FH-W Thermostat Device Profile
’s mobile dashboard. See Modify TA652FH-W Thermostat device profile’s mobile dashboard.
Update Detail Dashboard¶
- First, clear TA652FH-W Thermostat device profile’s mobile dashboard.
- Next, delete this dashboard: Dashboards –> Click in the row of
TA652FH-W Thermostat (For Mobile App)
–> Popup dialog: Are you sure you want to delete …? –> Yes.
Office center - TA652FH-W Thermostats¶
Dashboard states¶
Office state¶
Office state
is root state.
- Dashboard bar:
- : Click here to skip to root state. Since default state is root state, click here and there is no response.
- Thermostats List:
- Fields:
- Thermostat name, Label, active.
- Room temperature, Floor Temperature, Setpoint, Unit, xPos, yPos.
- Actions:
- : Skip to Map state.
- : Open a dialog, to add a new thermostat.
- : Skip to Chart state.
- : Open a dialog, to edit a thermostat.
- : Open a dialog, to edit a thermostat.
- Map widget:
- : Open a box, to show some text.
- : Skip to Chart state.
Map state¶
- Map widget:
- : Click to enter drag-drop mode, you can modify the position of the thermostat. Click again to save the modification and exit drag-drop mode.
Chart state¶
Import Office Center Dashboard¶
Tip
A Dashboard file can only be imported once. If you have already imported it, you do not need and cannot repeat the import.
If you have already imported it, you can skip this step.
In order to use this dashboard, you must to create TA652FH-W Thermostat Device Profile
. If it doesn’t exist, you can import it. See Import Device Profile of TA652FH-W Thermostat.
- Download
office_center___ta652fh_w_thermostats.json
. - Dashboards –> + –> Popup dialog: Import dashboard –> Drag and drop Office center dashboard File –> Import.