********************************************** TA652FH-W --- Floor Heating Wi-Fi Thermostat ********************************************** .. CAUTION:: 1. Turn off all electrical devices (e.g. heater, cooler) that are connected to the unit before installation and maintenance. 2. The installer must be a trained service personnel 3. Disconnect the power supply before maintenance. 4. It must be mounted on a dry clean indoor place. 5. Do not expose this unit to moisture. 6. Do not expose this unit to dipping or splashing. Introduction ============= T65 is a controller that controls heater/cooler on or off to maintain room temperature at a desired level. When **Heat mode** is used, **Internal sensor**, **Floor sensor** and **combined sensor** can be selected for different application. When **Cool mode** is selected, Only **Internal sensor** will be used. Feature List ============= * Voltage supply: 230Vac * Temperature display in °C or °F * Temperature measurable range : 0 - 50 °C * Selection of Heat/Cool * Adaptive control * 7days / 5+1+1days, 1day program, no program. * EEPROM stores all settings * Adjustable control span * Short cycle protection for compressor Wiring ======= **NOTE:** Power supply of TA652FH-W is 230Vac. .. table:: :widths: auto =========== ================ Terminals Device =========== ================ L 230Vac Live N 230Vac Neutral LO Heater / Cooler T1 Floor Sensor 1 T2 Floor Sensor 2 =========== ================ Pull all cables back into the wall beforehand to avoid trapping of wires. Do not use any metal conduits or cables provided with metal sheaths. Recommend adding fuse or protective device in the live circuit. =========================================== .. image:: /_static/device/ta652fh-w/ta652fh-w-specifications/wiring-1.png :width: 54% .. image:: /_static/device/ta652fh-w/ta652fh-w-specifications/wiring-2.png :width: 19% Mounting ======== .. image:: /_static/device/ta652fh-w/ta652fh-w-specifications/mounting-1.png :width: 32% .. image:: /_static/device/ta652fh-w/ta652fh-w-specifications/mounting-2.png :width: 32% .. image:: /_static/device/ta652fh-w/ta652fh-w-specifications/mounting-3.png :width: 32% 1. Wiring the terminals. 2. Put into junction box. 3. Mount the bottom plate of LCD board into junction box. 4. Connect the wire to the LCD board. 5. Assemble the Top and bottom plate of LCD Board. Dimension in mm: ================ .. image:: /_static/device/ta652fh-w/ta652fh-w-specifications/dimension-1.png :width: 50% .. image:: /_static/device/ta652fh-w/ta652fh-w-specifications/dimension-2.png :width: 30% LCD Interface ============= LCD Indication --------------- .. image:: /_static/device/ta652fh-w/ta652fh-w-specifications/lcd_indication.png :width: 40% .. table:: :widths: auto === =============================================================================== sn item === =============================================================================== 1 Time 2 Room Temperature 3 Current Set Point 4 Temperature Unit 5 Current Program 6 Heat / Cool Mode 8 Output is On (when appear) 8 Wi-Fi (appear when connected to router) 9 Mode Key: Press to **internal setting 1**. Long hold to **internal setting 2**. 10 Clock Key: Press to **set clock**. Hold to **Program** the Schedule 11 Short Press: Fan Key, Long Hold: On/Off Key 12 Up/Down key: Adjust Set point or Value of setting. 13 Blank: the area outside of the previous five keys === =============================================================================== .. |icon_mode| image:: /_static/device/ta652fh-w/ta652fh-w-specifications/icon_mode.png :scale: 50% .. |icon_clock| image:: /_static/device/ta652fh-w/ta652fh-w-specifications/icon_clock.png :scale: 50% .. |icon_onoff| image:: /_static/device/ta652fh-w/ta652fh-w-specifications/icon_onoff.png :scale: 50% .. |icon_up| image:: /_static/device/ta652fh-w/ta652fh-w-specifications/icon_up.png :scale: 50% .. |icon_down| image:: /_static/device/ta652fh-w/ta652fh-w-specifications/icon_down.png :scale: 50% .. |icon_blank| replace:: **[blank]** Turn On/Off the thermostat --------------------------- Hold |icon_onoff| to turn On / Off the thermostat. When the thermostat is Off. No Output will be activated. Clock setting ------------- **Normally the clock is automatically set once Wi-Fi is connected and synchronize for each day. So manual set is not necessary when it is online.** * Press |icon_clock| to start the setting * Press |icon_up| / |icon_down| to change the day of week * Press |icon_clock| again to confirm day of week setting and start to adjust hour * Press |icon_up| / |icon_down| to change the hour * Press |icon_clock| again to confirm hour setting and start to adjust minutes * Press |icon_up| / |icon_down| to change the minutes * Press |icon_clock| again to confirm minutes setting and start to adjust day of week * Press |icon_blank| to confirm or leave the clock setting. Or return after no key pressed for 20 seconds. Clock synchronization ^^^^^^^^^^^^^^^^^^^^^^^^^ When Wi-Fi is connected and time synchronization is need. Please use the App for time synchronization. Schedule Programming --------------------- When **1 day** / **5+1+1 day** / **7day program** is selected in internal setting. * Hold |icon_clock| to start the setting. * Press |icon_up| / |icon_down| to adjust the day of week * Press |icon_clock| to confirm. * Press |icon_up| / |icon_down| to adjust the time of schedule * Press |icon_clock| to confirm. * Press |icon_up| / |icon_down| to adjust the setpoint * Press |icon_clock| to confirm. * Press |icon_blank| to confirm return. Override Temperature --------------------- The Set point can be adjusted by |icon_up| / |icon_down|. When it is in program mode, the set point will be overwritten until the next time slot. |icon_clock| can be pressed to release the override status. Internal parameter setting 1 ----------------------------- * Operation: * Press |icon_mode| key to start the setting * Press |icon_up| / |icon_down| to adjust the value * Press |icon_blank| to confirm and move to next setting ===== ============================= =========================== ===================== ID Items Value Default Value ===== ============================= =========================== ===================== P00 User Interface Screen Saver 0-3 0 P01 Screen Saver Count down 0-120 20 P02 Display unit °C / °F °C P03 Time Display unit 12/24 12 P04 Temperature Offset -5°C - 5°C, -10°F-10°F 0°C P05 Switching Differential Heat 2 - 4°C, 4 - 8°F 2°C P06 Switching Differential Cool 2 - 4°C, 4 - 8°F 2°C P07 Program mode | No program (0) / 3 | 1day program (1) / | 5+1+1 program (2) / | 7day program (3) P08 Adaptive Control Enable / Disable Disable P09 System Mode Heat / Cool Heat P10 Sensor Mode | Internal Sensor / Internal Sensor | External Sensor / | Combined mode P11 Floor temperature limited 20-40°C, 68-104°F 40°C ===== ============================= =========================== ===================== * User Interface Screen Saver: The thermostat will go to screen saver mode after no key for certain period. * **Mode 0**: Nothing will be displayed in screen saver mode. * **Mode 1**: Only room temperature will be displayed in screen saver mode. * **Mode 2**: Room temperature and Time will be displayed in screen saver mode. * **Mode 3**: Display all in screen saver mode. * Screen Saver Count Down: The count down time (in seconds) to screen saver mode. * Display Unit: Temperature unit in Celsius or Fahrenheit. * Time Display Unit: 12/24. * Temperature offset: The temperature of internal sensor can be calibrated from -5°C - +5°C in case there is temperature difference between actual value and thermostat. * Switching Differential: The difference between switching the heating or controller on and off .. image:: /_static/device/ta652fh-w/ta652fh-w-specifications/switching-differential-1.png :width: 49% .. image:: /_static/device/ta652fh-w/ta652fh-w-specifications/switching-differential-2.png :width: 49% * Program Mode: * 0: **No Program** Mode, the thermostat control the temperature simply according to single setpoint. * 1: **1 day** program, the thermostat control the temperature according to single schedule. * 2: **5+1+1 day** program, the thermostat control the temperature according to 5 +1+1 schedule (Mon to Fri, Sat, Sun). * 3: **7 days** program, the thermostat control the temperature according to 7day program (individual program for each day). * Adaptive control When this function is enable, the thermostat learns the time taken to reach the desired setpoint and turn on the heating / cooling earlier so that the room temperature will reach the setpoint at desired schedule. This is no effect when **No program** is selected. * Heat / Cool Mode When **Heat mode** is selected, the thermostat control the room temperature with heating. **Room Sensor**, **Floor Sensor** or **Combined sensor** can be selected. When **Cool mode** is selected, the thermostat control the room temperature with cooling. Only **Room Sensor**, will be used. * Sensor Mode There are 3 different settings of sensor control for Heat Mode. (For Cool Mode. Only Room sensor will be used) * Room sensor Thermostat control the room temperature based on Room Sensor * Floor sensor Thermostat control the room temperature based on Floor Sensor * Combined Floor-/Room sensor Thermostat control the room temperature based on Room Sensor. And the output will be off if floor temperature above “floor temperature limited” for protection. * Floor temperature limited It is the temperature limited for floor sensor. When the **Heat Mode** and **Combined Sensor** are selected. The output will turn off when floor sensor sense the temperature to be higher than **floor temperature limited**. Internal parameter setting 2 ----------------------------- * Operation: * Hold |icon_mode| key to start the setting * Press |icon_up| / |icon_down| to adjust the value * Press |icon_blank| to confirm and move to next setting ===== ============================================= =========== ==================== ID Items Value Default Value ===== ============================================= =========== ==================== P19 Clear Wi-Fi Configuration Yes or No No P20 Clear Parameter setting (restore default) Yes or No No Adr Address ... Read only, eg: 75C68 ===== ============================================= =========== ==================== * Clear Wi-Fi Configuration: When set to yes, the SSID and Password stored in the thermostat will be cleared so another SSID and Password can be set again. * Clear Parameter setting: When set to yes, all internal parameter setting will be restored to default value in next power on (reset) * Address: The last 5 characters of the MAC address Minimum off time ----------------- The minimum off time for Heat mode is 5 seconds and 4 minutes for Cool mode. Technical Data ---------------- ========================= ========================== Power supply: 195-250 Vac Relay Contact Voltage: 230Vac Max. 50/60 Hz Relay Contact Current: 16A Max. Sensing Element: 103AT Terminals: 2 sq. mm Cable Operating Temperature: 32 - 122 °F / 0 - 50 °C Storage Temperature: 23 - 122 °F / -5 - 50 °C Operating Humidity: 5-95%RHnon-condensing ========================= ==========================